Suctioning a Trach Tube at the Right time Using the Right Technique
Tracheostomy care procedure, this is a high-risk
procedure and must be performed in the care of a someone expert in tracheostomy
care procedure in Lansing. Apart from that, care providers must adhere to
evidence-based guidelines to avoid poor outcomes. These patients are highly
susceptible to infection, airway obstruction and impaired ventilation. A
patient can avoid these and other lethal complication by working with trained
and certified nurses for tracheostomy care procedure in Lansing.
So, in this article, we bring you these guidelines to open and close
suctioning.
Suctioning
a trach tube
Some trach tubes have single, and some have a
double lumen. And, the trach tube may be cuffed or uncuffed. And, it may be
fenestrated or unfenestrated. Different trach tubes require specific
management. For example, if you are suctioning a fenestrated tube, make sure
that you are inserting a plain inner tube as the suction catheter can puncture
the opening of the trach tube. Proper suctioning involves the following:
Proper assessment
Proper oxygenation management
Using correct suction pressure
Liquefaction of secretions
Using the right suction catheter
Correct patient and evaluation.
Apart from
that, make sure that emergency equipment is available.
When to
suction
Some patients cannot clear their airways. So, they need to get suctioning done. Setting
a schedule for suctioning will not work as each patient needs tailored timing
for suctioning. Changes in respiratory rate, increased work of breathing,
copious secretions, wheezing, decreased oxygen saturation and the patient is
unable to clear secretion, these are the cases when suctioning is required.
Here it is essential to assess the patient for the history of allergies and
asthma.
Suctioning
technique
First of all, hyper oxygenate the patient. Ask
the patient to take a few deep breaths (2 or 3). After that, use a manual
ventilator bag to administer 4 to 6 compressions. Activate the hyperoxygenation
button when you are taking care of a ventilator patient. According to the
experts, the suction pressure of up to 120 mm Hg is ideal for open-system
suctioning. And, when it is closed-system suctioning, the suction pressure
should be up to 160 mm Hg. There should be maximum three catheter passes for
each session. Suction during catheter extraction can last up to 10 seconds.
Always allow 20 to 30 seconds between each pass. When it is for open-system
suctioning, make sure that the catheter size does not exceed the inner radius
of the internal trach tube.
When it comes to determining the appropriate-size
French catheter, measure the size of the internal trach tube and divide it by
two. Now multiply the result by 3. Care providers often use a #12 French
catheter for closed suctioning. Calculate the distance needed for insertion.
According to experts, in the case of an open system, it should be 0.5 to 1 cm
past the distal end and in the case of a closed system, it should be 1 to 2 cm
past the distal end.